SWR, return loss and reflected power
Work out the SWR of an antenna or load from its impedance and the line impedance, the reflection coefficient, the return loss in dB and the power going back to the transmitter.
When a radio-frequency line (a coaxial cable) ends in a load of its own impedance, all the power goes into the load. If the impedance is different, part of the wave bounces back towards the transmitter. The forward and reflected waves add up and form a standing wave with voltage maxima and minima along the cable. The ratio between maximum and minimum is the SWR (standing wave ratio).
Reflection coefficient and SWR
Z₀ is the line impedance and ZL the load impedance. With a resistive load, SWR is the larger of the two divided by the smaller: a 75 Ω antenna on a 50 Ω cable gives Γ = 0.2 and SWR = 1.5. A 33.3 Ω load would give the same SWR: that is why SWR alone does not tell whether the antenna is «long» or «short». With a complex load (with reactance), Γ is computed with complex numbers and an antenna analyser is needed.
Return loss and reflected power
| SWR | |Γ| | Return loss | Reflected power | Mismatch loss |
|---|---|---|---|---|
| 1.1 | 0.048 | 26.4 dB | 0.2 % | 0.01 dB |
| 1.5 | 0.200 | 14.0 dB | 4.0 % | 0.18 dB |
| 2 | 0.333 | 9.5 dB | 11.1 % | 0.51 dB |
| 3 | 0.500 | 6.0 dB | 25 % | 1.25 dB |
Coaxial cable impedance and attenuators
D is the inner diameter of the shield and d that of the centre conductor; εr the dielectric permittivity (solid polyethylene 2.25, foam about 1.5). For testing and measurement, π attenuators of the same impedance are used, which also improve the SWR the transmitter sees: with an A dB attenuator, return loss rises by 2 · A dB. In a π pad, with K = 10^(A/20): series R = Z₀ (K² − 1) / (2K) and shunt R = Z₀ (K + 1) / (K − 1); a 6 dB 50 Ω pad has 37.4 Ω in series and 150.5 Ω in shunt.
Several ways to get each value
- The SWR: from the load and line impedances.
- The load giving a measured SWR: ZL = Z₀ · SWR or Z₀ / SWR.
- With a forward and reflected power meter: Γ = √(Pr / Pf).
- With return loss from an analyser: Γ = 10^(−RL/20).
Frequently asked questions
How is SWR calculated?
From the reflection coefficient Γ = |ZL − Z0| / (ZL + Z0): SWR = (1 + Γ) / (1 − Γ). A 75 Ω antenna on 50 Ω coax: Γ = 25 / 125 = 0.2 and SWR = 1.2 / 0.8 = 1.5. With a resistive load it is simply the larger impedance over the smaller: 75 / 50 = 1.5.
What SWR is acceptable?
Up to 1.5 is good (4 % of the power comes back) and up to 2 acceptable (11 %). Above 3 many transmitters fold back power to protect themselves.
What is return loss?
The same as SWR but in decibels: RL = −20 · log Γ. The higher, the better: 14 dB equals SWR 1.5; 20 dB, 1.22; 10 dB, 1.92.
Is reflected power lost?
On a lossless line, reflected power is reflected again at the transmitter and ends up reaching the antenna; what is really lost is the mismatch loss, −10 · log(1 − Γ²): 0.18 dB at SWR 1.5.