Timber beam calculator: maximum span and depth
Work out the maximum span of a timber beam, joist or lintel from its section, strength class (C24, GL24h…) and load, or the depth needed for a span.
A timber beam or joist supported at both ends has to carry its load without breaking (bending and shear) and without bending too much (deflection). The calculator gives the maximum span of a section under a load, or the depth, width or load it allows for a span. It is a preliminary design based on Eurocode 5: for a real project, have it signed off by an engineer.
The three checks
The load per metre is the load per m² times the beam spacing. The design load qd uses an average factor of 1.4 (1.35 for dead load and 1.5 for imposed load). Design strengths are fd = kmod · fk / γM, with kmod = 0.8 (medium-term load, indoors) and γM = 1.3; kcr = 0.67 allows for splits. Deflection uses the unfactored load and I = b · h³ / 12. The maximum span is the smallest of the three.
Strength classes
| Class | fm,k (MPa) | fv,k (MPa) | E0,mean (MPa) | Timber |
|---|---|---|---|---|
| C16 | 16 | 3.2 | 8,000 | Ordinary-grade pine |
| C18 | 18 | 3.4 | 9,000 | Radiata and maritime pine |
| C24 | 24 | 4.0 | 11,000 | Scots pine, spruce, the most common |
| C30 | 30 | 4.0 | 12,000 | Selected timber |
| GL24h | 24 | 3.5 | 11,500 | Glued laminated timber |
| GL28h | 28 | 3.5 | 12,600 | Glued laminated timber |
| D30 | 30 | 3.9 | 11,000 | Oak and other hardwoods |
Several ways to get each value
- The maximum span of a beam you already have: enter its section and the load.
- The depth needed for a span: enter the span and clear the depth.
- The spacing between joists for a section and a span: clear the spacing.
- The load allowed on an existing floor: with the span and the section, clear the load.
- Rule of thumb: for C24 house floors, depth is about L/20 to L/22 (200 mm for 4 to 4.5 m).
Tips
- Deflection almost always governs: if it is not enough, increase the depth rather than the width (stiffness grows with h³).
- Over time timber creeps and deflection grows (kdef = 0.6 indoors): so do not use up the whole deflection limit.
- Supports need at least 80 to 100 mm of bearing and protection from damp.
- For steel beams or other supports and loads, use the beam calculator.
Frequently asked questions
What span can a 75 × 200 mm timber beam cover?
In C24, at 500 mm centres and with 3 kN/m² (house floor), about 4.5 m: deflection L/300 governs (bending alone would allow 5.3 m). At 400 mm centres, almost 4.9 m.
How is a timber beam designed?
Check bending (M = q·L²/8 against fm,d · b·h²/6), shear (V = q·L/2 against fv,d · kcr · b·h / 1.5) and deflection (5·q·L⁴ / 384·E·I against L/300). The maximum span is the smallest of the three.
What is C24 timber?
A strength class from EN 338: 24 MPa characteristic bending strength and 11,000 MPa modulus of elasticity. It is the most common grade for structural pine and spruce. Glulam GL24h has similar values but is more uniform and comes in large depths.
Why does deflection usually govern?
Timber is strong but not very stiff (E of 8,000 to 14,000 MPa, 15 to 25 times less than steel). For spans over 3 or 4 m, the beam bends too much before it breaks.