Skip to content
EN
  • Español
  • English
Advertisement

Fluid properties vs temperature

Data sheets for water, steam, gases, refrigerants, oils, glycols and food: density, viscosity, specific heat and vapour pressure at any temperature.Version 3 · First version: November 20, 2026 · Remastered: November 22, 2026

Fill in every field but one and the missing one is calculated. You can type in any of them.

Type it in to find the temperature at which the fluid has it.
Advanced options (6)

They come with a typical value: change it only if you know it.

It changes the density of gases and steam and the boiling point of liquids. 1 atm = 1.01325 bar.
°C
Dynamic viscosity—
Freezing temperature—
Dew temperature at that pressure—
Temperature glide (dew − bubble)—
Latent heat of vaporisation at that temperature—
Saturated liquid density—
Saturated vapour density—
Kinematic viscosity—
Specific heat—
Thermal conductivity—
Prandtl number—
Vapour pressure—
Boiling (or condensing) temperature at that pressure—
Enthalpy (from 0 °C; steam, from liquid water at 0 °C)—
Compressibility factor Z—
Molar mass—
Specific volume—
Lowest temperature of the data at that pressure—
Highest temperature of the data at that pressure (for liquids, their boiling point)—

Use this calculator for reference only, as we cannot guarantee that the results are free of errors.

Disclaimer

https://dyaii.es/en/fluid-properties/

Advertisement

A fluid’s density and viscosity change with temperature (and, for gases and steam, with pressure), and so do the Reynolds number, the pressure drop in a pipe and the power of a pump. Choose the fluid, its temperature and its pressure and the calculator gives its data sheet: density, dynamic and kinematic viscosity, specific heat, thermal conductivity, Prandtl number, vapour pressure, boiling point at that pressure, enthalpy, compressibility factor and molar mass. The other way round, from a measured density it tells you the temperature. Below you get the table over its whole range, ready to print or download as Excel, and the six data sheets of all the fluids.

The other fluid calculators (pressure drop, Reynolds, pumps…) have a “See data sheet” button next to the fluid that opens this page with the same fluid and temperature.

Formulas

ν = μ / ρ

Kinematic viscosity (ν) is dynamic viscosity (μ) divided by density (ρ). 1 cSt = 1 mm²/s = 10⁻⁶ m²/s and 1 cP = 1 mPa·s.

  • Liquid water (sheet A): IAPWS tables from 0 to 100 °C; above that, up to 300 °C, the saturated-liquid density (IAPWS) and Vogel’s viscosity. Vapour pressure with the Wagner–Pruss equation.
  • Steam (sheet B): saturated or superheated from 0.01 to 100 bar and up to 600 °C, as a real gas: ρ = p · M / (Z · R · T), with Pitzer’s Z factor. Typical error below 2 % in density and 3 % in enthalpy; for exact saturated steam, use the steam table.
  • Gases (sheet D): real gas with Z = 1 + (B⁰ + ω · B¹) · pr / Tr (Pitzer), Sutherland’s law for viscosity and ideal-gas specific heat, cp = a + b·T + c·T² + d·T³. Near the critical point (CO₂ at 50 bar, for example) the error grows. If the gas liquefies at that pressure, the calculator says so (Lee–Kesler vapour pressure).
  • Liquids, oils and solutions (sheets C, E and F): their reference value (at 20 °C, or 40 °C for diesel and ISO VG oils) corrected for temperature: density with its thermal expansion and viscosity with the Lewis–Squires correlation, μ-0.2661 = μref-0.2661 + (T − Tref) / 233 (μ in cP).
  • Vapour pressure: Antoine equation, log₁₀ p = A − B / (C + T), with p in mmHg and T in °C. Where the vapour pressure reaches the chosen pressure is the boiling point, the end of each liquid’s range.
  • Solutions: water with ethylene or propylene glycol and brines, with their usual density, viscosity, specific heat and freezing point (ASHRAE).

Worked examples

  1. Water at 60 °C: ρ = 983.2 kg/m³ and μ = 0.467 mPa·s, so ν = 0.467 / 983.2 = 0.475 cSt: less than half the value at 20 °C (1.003 cSt).
  2. Air at 100 °C: ρ = 1.204 · 293.15 / 373.15 = 0.946 kg/m³ and μ = 0.0217 mPa·s, 20 % more viscous than at 20 °C.
  3. At what temperature does water have 983.2 kg/m³? At 60 °C.
  4. Steam at 10 bar absolute: it condenses at 179.9 °C; saturated it has about 5.1 kg/m³, so 1 kg takes up almost 0.2 m³.
  5. Propane at 10 bar and 20 °C: the calculator warns that it is liquid (at 20 °C it liquefies above about 8.4 bar).
Advertisement

Using the data

  • For the Reynolds number and the pressure drop, choose the same fluid and temperature: those calculators already use these data (“Keep calculating” buttons).
  • An ISO VG 46 hydraulic oil has 46 cSt at 40 °C, but at 0 °C it goes above 400 cSt: on a cold start the pump works much harder.
  • To change units (cP, cSt, Pa·s, kg/m³, lb/ft³…), use each result’s drop-down.
  • For a glycol cooling circuit, choose a solution that freezes a few degrees below the lowest temperature in the circuit.
  • The values are the usual handbook figures for engineering calculations; for a specific product, the manufacturer’s data sheet rules.

Sheet A. Liquid water

Above 100 °C, at its vapour pressure or higher (otherwise it boils).

T (°C)ρ (kg/m³)μ (mPa·s)ν (cSt)cp (kJ/(kg·K))k (W/(m·K))Prpv (kPa)
0999.81.7911.7924.2170.57113.24—
20998.21.0021.0034.1820.6036.942.34
40992.20.6530.6584.1790.6314.337.39
60983.20.4660.4744.1850.6532.9919.95
80971.80.3540.3644.1970.6702.2247.42
100958.40.2820.2944.2160.6821.74101.42
120943.10.2320.2464.2450.6881.43198.67
140926.10.1970.2124.2850.6901.22361.53
160907.50.1710.1884.3390.6861.08618.23
180887.00.1510.1704.4080.6770.981,002.81
200864.70.1350.1564.4970.6630.921,554.94
220840.30.1230.1464.6100.6440.882,319.61
240813.40.1120.1384.7600.6200.863,346.96
260783.70.1040.1334.9800.5900.884,692.28
280750.40.0970.1295.2800.5560.926,416.58
300712.30.0910.1285.7500.5161.018,587.87

Sheet B. Steam

Saturated steam at each absolute pressure. In the calculator, also superheated up to 600 °C.

p (bar)T sat (°C)ρ (kg/m³)v (m³/kg)μ (μPa·s)h (kJ/kg)Z
0.581.30.3083.24911.32,6530.993
1.099.60.5881.70012.02,6880.988
2.0120.21.1230.89012.82,7270.981
5.0151.82.6440.37814.12,7880.964
10.0179.95.0710.19715.22,8420.943
20.0212.49.7940.10216.52,9050.911
50.0263.923.8700.04218.63,0070.845
100.0311.048.1420.02120.53,1010.770

Sheet C. Liquids

At 20 °C and 1 atm. Tb: boiling point at 1 atm (Antoine equation).

LiquidFormulaM (g/mol)ρ (kg/m³)μ (mPa·s)cp (kJ/(kg·K))pv (kPa)Tb (°C)
1,1,2-TrichloroethaneC₂H₃Cl₃133.401,4401.201.132.20113.7
1,2-DichloroethaneC₂H₄Cl₂98.951,2530.841.298.2683.8
1,4-DioxaneC₄H₈O₂88.111,0331.311.723.84101.3
1-ButanolC₄H₁₀O74.128102.952.390.55117.7
1-HexeneC₆H₁₂84.166730.262.1819.9963.5
1-OcteneC₈H₁₆112.227150.472.151.75121.3
1-PentanolC₅H₁₂O88.158154.002.360.16138.0
1-PropanolC₃H₈O60.108032.262.391.9497.2
2-ButanolC₄H₁₀O74.128073.702.711.5299.5
Ethyl acetateC₄H₈O₂88.119000.451.929.8476.7
Methyl acetateC₃H₆O₂74.089320.381.9222.9756.9
Vinyl acetateC₄H₆O₂86.099320.431.9712.0372.7
AcetoneC₃H₆O58.087900.322.1624.7356.1
Acetic acidC₂H₄O₂60.051,0491.222.053.39117.9
Acrylic acidC₃H₄O₂72.061,0511.302.0911.5879.4
Butyric acidC₄H₈O₂88.119581.601.990.10162.2
Formic acidCH₂O₂46.031,2201.782.154.50100.7
Propionic acidC₃H₆O₂74.089931.102.060.35140.9
Acetic anhydrideC₄H₆O₃102.091,0820.901.820.50138.6
AnilineC₆H₇N93.131,0224.402.060.06184.0
BenzeneC₆H₆78.118790.651.7410.0180.1
CyclohexaneC₆H₁₂84.167790.981.8510.3480.7
ChlorobenzeneC₆H₅Cl112.561,1060.801.331.21131.7
ChloroformCHCl₃119.371,4890.570.9621.0961.7
DichloromethaneCH₂Cl₂84.931,3260.441.1946.8140.2
Diethylene glycolC₄H₁₀O₃106.121,11835.702.310.00245.1
Carbon disulfideCS₂76.131,2630.371.0039.6746.2
StyreneC₈H₈104.159060.761.750.60145.2
EthanolC₂H₆O46.077891.202.445.8578.3
EthanolamineC₂H₇NO61.081,01824.002.660.03171.4
Diethyl etherC₄H₁₀O74.127130.232.3358.6734.6
EthylbenzeneC₈H₁₀106.178670.681.720.94136.2
EthylenediamineC₂H₈N₂60.108991.602.871.15117.3
Ethylene glycolC₂H₆O₂62.071,11321.002.410.01197.5
IsopentaneC₅H₁₂72.156200.222.2876.6427.9
Isopropanol (2-propanol)C₃H₈O60.107862.402.604.1282.2
m-XyleneC₈H₁₀106.178640.621.720.82139.1
Methyl methacrylateC₅H₈O₂100.129440.631.913.7096.5
MethanolCH₃OH32.047910.592.5313.0064.5
MethylcyclohexaneC₇H₁₄98.197690.731.884.83100.9
Methyl ethyl ketone (MEK)C₄H₈O72.118050.422.209.4579.6
Methyl isobutyl ketone (MIBK)C₆H₁₂O100.168010.582.131.93116.2
N,N-DimethylformamideC₃H₇NO73.109440.922.060.38149.7
n-DecaneC₁₀H₂₂142.297300.922.210.12174.1
n-HeptaneC₇H₁₆100.216840.412.244.7298.4
n-HexaneC₆H₁₄86.186590.312.2616.1768.7
n-NonaneC₉H₂₀128.267180.712.210.41150.8
n-OctaneC₈H₁₈114.237030.542.221.39125.7
n-PentaneC₅H₁₂72.156260.242.3256.5536.1
NitrobenzeneC₆H₅NO₂123.111,2042.031.510.02210.7
NitromethaneCH₃NO₂61.041,1370.631.743.65101.2
o-XyleneC₈H₁₀106.178800.811.760.65144.4
p-XyleneC₈H₁₀106.178610.651.710.87138.3
PyridineC₅H₅N79.109820.951.682.09115.2
Carbon tetrachlorideCCl₄153.811,5940.970.8612.1776.7
TolueneC₇H₈92.148670.591.702.91110.6
TrichloroethyleneC₂HCl₃131.381,4640.570.957.1687.3

Sheet D. Gases

At 20 °C and 1 atm. Tc and pc: critical temperature and pressure.

GasFormulaM (g/mol)ρ (kg/m³)μ (μPa·s)cp (kJ/(kg·K))k (W/(m·K))Tc (°C)pc (bar)
AirN₂ + O₂28.961.20418.131.0020.0258-140.637.7
NitrogenN₂28.011.16517.571.0370.0254-147.033.9
OxygenO₂32.001.33120.350.9170.0262-118.550.4
HydrogenH₂2.020.0848.8414.3070.1766-240.013.0
Carbon dioxideCO₂44.011.83914.640.8390.016031.173.8
Carbon monoxideCO28.011.16517.561.0370.0247-140.235.0
MethaneCH₄16.040.66810.892.2070.0331-82.546.0
EthaneC₂H₆30.071.2609.211.7340.020832.248.7
PropaneC₃H₈44.101.8668.051.6440.017396.742.5
n-ButaneC₄H₁₀58.122.4957.431.6830.0155152.038.0
AmmoniaNH₃17.030.7159.922.0990.0239132.5112.8
Sulphur dioxideSO₂64.072.70812.530.6190.0095157.778.8
Hydrogen sulphideH₂S34.081.42812.590.9920.0139100.189.4
ChlorineCl₂70.912.98713.250.4780.0086144.177.1
EthyleneC₂H₄28.051.1739.941.5340.02009.250.4
ArgonAr39.951.66222.280.5200.0173-122.348.7
HeliumHe4.000.16619.675.1940.1494-268.02.3

Sheet E. Oils and fuels

Kinematic viscosity vs temperature (the last value, at 100 °C or at the end of its range).

Fluidρ 20 °C (kg/m³)ν 0 °C (cSt)ν 20 °C (cSt)ν 40 °C (cSt)ν 100 °C (cSt)Range (°C)
Diesel8317.44.63.01.5-10 … 80
Hydraulic oil ISO VG 32881336.086.332.05.4-10 … 100
Hydraulic oil ISO VG 46886577.3133.846.06.8-10 … 100
Hydraulic oil ISO VG 688911,033.2214.868.08.7-10 … 100
Hydraulic oil ISO VG 22876186.954.322.04.3-20 … 100
Hydraulic oil ISO VG 1008971,824.1341.8100.011.10 … 120
Kerosene8002.92.01.40.6-40 … 150
Petrol (gasoline)7400.80.60.50.4-30 … 60
Hydraulic oil ISO VG 1087156.420.810.02.6-20 … 100
Oil ISO VG 1509023,173.1548.1150.014.60 … 120
Oil ISO VG 2209075,537.4867.2220.018.60 … 120
Oil ISO VG 320912—1,351.3320.023.75 … 120
Oil ISO VG 460917—2,102.3460.029.510 … 120
Transformer oil88345.317.99.02.5-30 … 100
Mineral thermal oil877302.879.630.05.20 … 300
Silicone oil 50 cSt96583.655.038.417.0-40 … 200
Engine oil SAE 308971,861.4344.4100.011.0-10 … 120
Engine oil SAE 409022,858.9503.8140.014.00 … 120

Sheet F. Solutions

At 20 °C, percentage by mass. For a cooling circuit, choose one that freezes below the lowest temperature.

Solutionρ (kg/m³)μ (mPa·s)cp (kJ/(kg·K))k (W/(m·K))Freezes at (°C)
Seawater1,0251.083.990.596-1.9
Water with 30 % glycol1,0402.503.700.500-14.1
Water with 10 % ethylene glycol1,0111.303.970.565-3.2
Water with 20 % ethylene glycol1,0241.753.820.530-7.8
Water with 40 % ethylene glycol1,0523.303.480.460-22.3
Water with 50 % ethylene glycol1,0654.403.290.420-33.8
Water with 10 % propylene glycol1,0081.504.070.560-3.3
Water with 20 % propylene glycol1,0172.103.980.520-7.1
Water with 30 % propylene glycol1,0263.003.860.480-12.7
Water with 40 % propylene glycol1,0334.503.720.440-21.1
Water with 50 % propylene glycol1,0396.403.560.400-33.5
Sodium chloride brine 10 %1,0711.193.750.580-6.6
Sodium chloride brine 20 %1,1481.563.330.560-16.5
Calcium chloride brine 20 %1,1781.863.040.550-18.6
Calcium chloride brine 30 %1,2823.602.680.530-46.0

Solutions at any concentration

Concentration and freezing point. In the calculator, any concentration between these rows.

Solutioncρ (kg/m³)μ (mPa·s)cp (kJ/(kg·K))k (W/(m·K))Freezes at (°C)
Water with ethylene glycol (choose the %)10 %1,0111.303.970.565-3.2
Water with ethylene glycol (choose the %)20 %1,0241.753.820.530-7.8
Water with ethylene glycol (choose the %)30 %1,0382.403.660.495-15.0
Water with ethylene glycol (choose the %)40 %1,0523.303.480.460-22.3
Water with ethylene glycol (choose the %)50 %1,0654.403.290.420-33.8
Water with ethylene glycol (choose the %)60 %1,0776.003.090.385-52.0
Water with propylene glycol (choose the %)10 %1,0081.504.070.560-3.3
Water with propylene glycol (choose the %)20 %1,0172.103.980.520-7.1
Water with propylene glycol (choose the %)30 %1,0263.003.860.480-12.7
Water with propylene glycol (choose the %)40 %1,0334.503.720.440-21.1
Water with propylene glycol (choose the %)50 %1,0396.403.560.400-33.5
Water with propylene glycol (choose the %)60 %1,04310.503.380.360-48.0
Sodium chloride brine (choose the %)5 %1,0341.093.920.590-3.0
Sodium chloride brine (choose the %)10 %1,0711.193.750.580-6.6
Sodium chloride brine (choose the %)15 %1,1091.353.540.570-10.9
Sodium chloride brine (choose the %)20 %1,1481.563.330.560-16.5
Sodium chloride brine (choose the %)23 %1,1721.783.260.550-21.1
Calcium chloride brine (choose the %)10 %1,0841.303.640.575-5.4
Calcium chloride brine (choose the %)20 %1,1781.863.040.550-18.6
Calcium chloride brine (choose the %)25 %1,2282.502.860.540-29.4
Calcium chloride brine (choose the %)30 %1,2823.602.680.530-46.0

Sheet G. Refrigerants

Saturation (bubble) pressure vs temperature, and glide at 1 bar for blends. Approximate values: ±3 % in pressure.

RefrigerantCompositionM (g/mol)Tc (°C)pc (bar)p −20 °C (bar)p 0 °C (bar)p 20 °C (bar)p 40 °C (bar)Glide (K)
R32CH₂F₂52.0278.157.84.168.3515.0725.140.0
R134aCH₂FCF₃102.03101.140.61.332.965.7810.250.0
R1234yfCF₃CF=CH₂114.0494.733.81.523.195.9910.270.0
R1234ze(E)CF₃CH=CHF114.04109.436.40.972.184.327.740.0
R1233zd(E)CF₃CH=CHCl130.50166.536.20.180.481.082.170.0
R245faCF₃CH₂CHF₂134.05153.936.50.190.531.232.510.0
R22CHClF₂86.4796.249.92.475.039.1715.410.0
R404AR125/R143a/R134a (44/52/4)97.6072.137.33.146.2211.1118.400.8
R407CR32/R125/R134a (23/25/52)86.2086.246.32.825.6910.3117.247.1
R410AR32/R125 (50/50)72.5871.349.04.098.1614.6624.410.1
R448AR32/R125/R1234yf/R134a/R1234ze (26/26/20/21/7)86.2883.746.63.076.1411.0418.356.1
R449AR32/R125/R1234yf/R134a (24,3/24,7/25,3/25,7)87.2081.544.53.086.1311.0118.286.1
R452AR32/R125/R1234yf (11/59/30)103.5075.140.03.196.3211.2818.653.8
R454BR32/R1234yf (68,9/31,1)62.6078.152.73.917.7813.9423.120.9
R454CR32/R1234yf (21,5/78,5)90.8085.743.22.965.7910.2416.798.1
R507AR125/R143a (50/50)98.8670.637.13.216.3611.3718.830.0
R513AR1234yf/R134a (56/44)108.4096.537.71.523.266.2010.780.0
R290 (propane)C₃H₈44.1096.742.52.464.798.4413.770.0
R600a (isobutane)C₄H₁₀58.12134.736.30.721.573.045.350.0
R1270 (propylene)C₃H₆42.0891.145.63.085.8910.2416.550.0
R717 (ammonia)NH₃17.03132.3113.31.924.398.8015.950.0
R744 (carbon dioxide)CO₂44.0131.073.819.6334.6957.19—0.0

Sheet H. Food

At 20 °C (oils, at the temperature of their data).

FoodT (°C)ρ (kg/m³)μ (mPa·s)cp (kJ/(kg·K))k (W/(m·K))Freezes at (°C)
Olive oil2091184.001.970.170—
Sunflower oil2091958.001.990.165—
Soybean oil2092059.001.960.165—
Rapeseed oil2091472.001.960.165—
Coconut oil4090827.002.050.165—
Whole milk201,0322.003.890.530-0.5
Skimmed milk201,0351.603.950.560-0.5
Cream2099416.003.500.370-0.4
Beer201,0101.504.000.560-2.0
Wine209901.603.900.550-5.0
Vinegar201,0101.103.950.580-2.0
Semi-skimmed milk201,0331.803.920.545-0.5
Plain soy drink201,0302.503.850.530-0.5
Liquid whole egg201,0356.003.350.500-0.5
Liquid egg white201,0354.003.700.560-0.5
Meat stock201,0101.304.000.570-1.0
Light cooking cream, 18 %201,0108.003.700.450-0.5
Plain drinking yoghurt201,04030.003.800.530-0.6
Fish stock201,0081.204.020.575-1.0
Advertisement

Frequently asked questions

Why does a liquid’s viscosity drop when it is heated?

Because its molecules move more and hold on to each other less. Water’s viscosity falls to less than half from 20 to 80 °C; a hydraulic oil’s, to almost a tenth. That is why a pump or an oil line behaves so differently cold and hot.

And a gas’s?

It rises with temperature (Sutherland’s law): the molecules collide more and carry more momentum. Air at 100 °C is 20 % more viscous than at 20 °C.

What is the difference between dynamic and kinematic viscosity?

Dynamic viscosity (μ, in Pa·s or cP) measures resistance to sliding; kinematic viscosity (ν = μ / ρ, in m²/s or cSt) divides it by the density and is the one in the Reynolds number and in ISO VG oil grades.

Up to what temperature are the data valid?

Each fluid has its range, depending on the pressure: liquid water, from 0 °C until it boils (300 °C at most); steam, from where it condenses up to 600 °C and 100 bar; gases, from -50 to 500 °C without liquefying; liquids, from 0 °C to their boiling point; oils and solutions, the one in their sheet. Outside it, the calculator tells you why.

What are the data sheets?

Eight tables with the properties of every fluid on the site: A, liquid water; B, steam; C, 57 liquids; D, 17 gases; E, oils and fuels; F, glycol solutions and brines, also at any concentration; G, 22 refrigerants; H, food. They are at the end of this page, and every fluid calculator opens them with the “See data sheet” button.

Where do the data come from?

Water, from the IAPWS tables; air and gases, from the equation of state with Pitzer’s virial and Sutherland’s law; liquids, from their handbook reference values (Perry, CRC) corrected for temperature; oils, with Walther’s equation (ASTM D341) between 40 and 100 °C; glycols and brines, from the ASHRAE tables; refrigerants, from their critical constants and boiling point (NIST, ISO 817) with the Lee-Kesler, Rackett and Pitzer correlations, within about 3 % in pressure. The vapour pressure of liquids, with the Antoine equation.

Version history
  • Version 3 · November 22, 2026: Refrigerantes, glicoles y salmueras con la concentración que se quiera, alimentos y más aceites; al cambiar de fluido se ponen sus propios valores
  • Version 2 · November 22, 2026: Hojas de datos A a F: vapor de agua, 17 gases, más aceites y disoluciones, con la presión
  • Version 1 · November 20, 2026: Primera versión: 64 fluidos, cada uno en su rango de temperatura