Pipe pressure drop calculator with fittings

Calculate the pressure drop in a pipe with its elbows, tees and valves (Darcy-Weisbach and Colebrook). Also the flow rate, diameter or maximum length.

Fill in 3 of the 4 fields and the missing one is calculated. You can type in any of them.

pcs
pcs
pcs
pcs
pcs
pcs
Adds the sharp-edged inlet (K = 0.5) and the discharge into a tank (K = 1).
Coefficients of equipment, filters or fittings that are not in the list.
Mean velocity—
Reynolds number—
Friction factor (λ)—
Loss in the straight pipe—
Loss in the fittings—
Sum of K coefficients—
Equivalent length of the fittings—
Head loss in fluid column—
Loss per 100 m of pipe—
Pressure needed with the elevation change—
Fluid density—
Fluid dynamic viscosity—

Use this calculator for reference only, as we cannot guarantee that the results are free of errors.

Disclaimer

https://dyaii.es/en/pipe-pressure-drop-calculator/

Advertisement

Pressure drop is the pressure a pipe “eats up” as it moves a fluid: through friction with the walls and at every elbow, tee or valve along the way. With this calculator you get it for water, air, diesel, oils or any other fluid, and also the other way round: the flow rate that passes with a given drop, the diameter you need to stay below a certain drop, or the maximum pipe length.

How to use the calculator

  1. Choose the fluid. For water, its temperature is enough; for any other, enter its density and viscosity.
  2. Choose the pipe material: it sets its roughness, which you can change.
  3. Of these four values, enter three and leave empty the one you want to calculate: flow rate, inside diameter, length or pressure drop.
  4. If the pipe has fittings, enter how many of each type. If it runs from one tank to another, select “Tank inlet and outlet”. For a filter or a piece of equipment, add its K coefficient in “Other losses”.
  5. With the elevation change, the calculator also gives you the total pressure the pump has to supply.

Darcy-Weisbach equation

Δp = (λ · L / D + ΣK) · ρ · v² / 2

Where λ is the friction factor (dimensionless), L the pipe length (m), D its inside diameter (m), ΣK the sum of the fitting coefficients, ρ the fluid density (kg/m³) and v the mean velocity (m/s), which comes from the flow rate:

v = 4 · Q / (π · D²)

The first term is the major loss (the straight pipe) and the second, the minor loss (the fittings). Divided by ρ · g, the drop is expressed in metres of fluid column (hf).

Advertisement

Friction factor: Colebrook-White

The friction factor depends on the Reynolds number (Re = ρ · v · D / μ) and on the relative roughness ε / D:

Laminar (Re ≤ 2300): λ = 64 / Re
Turbulent: 1 / √λ = −2 · log₁₀( ε / (3.71 · D) + 2.51 / (Re · √λ) )

The Colebrook equation cannot be solved explicitly: the calculator solves it by iteration, starting from the Swamee-Jain approximation. It is the same as reading the Moody chart, but without reading errors.

Between Re = 2300 and 4000 the flow is transitional and no method is exact. If your result falls in that zone, treat it as an estimate.

Losses in elbows, tees and valves

Each fitting adds Δp = K · ρ · v² / 2. The coefficients are those of Crane TP-410, which depend on the diameter through fT (the fully turbulent friction factor of commercial steel), plus a Hooper K₁ / Re term for slow or viscous flow:

FittingK (Crane)K at DN 50
Standard 90° elbow30 · fT + 800 / Re0.57
Standard 45° elbow16 · fT + 500 / Re0.31
Tee, flow through the branch60 · fT + 500 / Re1.15
Open ball or gate valve8 · fT + 300 / Re0.15
Open globe valve340 · fT + 1500 / Re6.5
Swing check valve100 · fT + 1500 / Re1.9
Inlet from a tank (sharp-edged)0.5 + 160 / Re0.5
Discharge into a tank11

The equivalent length is the straight pipe that would lose the same as the fittings: Le = ΣK · D / λ. For a specific valve, the manufacturer's data (its Kv or its K) is better.

Roughness of materials

MaterialRoughness ε (mm)
Copper, brass, PVC, PE, PP0.0015
Stainless steel0.015
New carbon steel0.045
Galvanized steel0.15
Cast iron0.26
Rusted or scaled steel0.5
Concrete0.3 to 3 (1 on average)

Roughness grows over the years: in old steel pipes it is wise to calculate with 0.2 to 0.5 mm.

Worked example

10 m³/h of water at 20 °C through 100 m of steel pipe with a 50 mm inside diameter, with 4 90° elbows and 2 ball valves:

v = 4 · (10 / 3600) / (π · 0.05²) ≈ 1.415 m/s
Re = 998.21 · 1.415 · 0.05 / 0.0010016 ≈ 70,500 → turbulent
λ (Colebrook, ε / D = 0.0009) ≈ 0.0227
ΣK ≈ 4 · 0.586 + 2 · 0.157 ≈ 2.66
ρ · v² / 2 = 998.21 · 1.415² / 2 ≈ 999 Pa
Δp = (0.0227 · 100 / 0.05 + 2.66) · 999 ≈ 45,300 + 2,650 ≈ 47,980 Pa ≈ 0.48 bar

That is about 4.9 m of water column. The fittings are equivalent to 5.9 m of straight pipe.

ServiceVelocity (m/s)
Pump suction (water)0.5 to 1
Pump discharge (water)1 to 2.5
Water in buildings0.5 to 2
Oils and viscous liquids0.5 to 1.5
Compressed air6 to 10
Saturated steam20 to 40

A reasonable pressure drop in water is between 1 and 4 mbar per metre of pipe (10 to 40 m of water column per kilometre).

Advertisement

Frequently asked questions

What is pressure drop?

It is the pressure a fluid loses as it flows through a pipe, because of friction with the walls (major losses) and the changes of direction and cross-section in elbows, tees and valves (minor or local losses). The pump has to supply that pressure for the flow to circulate.

Which formula does the calculator use?

Darcy-Weisbach, Δp = λ · (L / D) · ρ · v² / 2, with the Colebrook-White friction factor λ (or 64 / Re in laminar flow). Fittings add Δp = K · ρ · v² / 2, with the K coefficients from Crane TP-410.

What velocity is recommended in a water pipe?

Between 1 and 2 m/s on the pump discharge and between 0.5 and 1 m/s on the suction. Above 3 m/s the pressure drop, noise, erosion and risk of water hammer increase a lot.

What is the difference from the Hazen-Williams formula?

Hazen-Williams is empirical and only valid for water at room temperature in turbulent flow. Darcy-Weisbach with Colebrook works for any fluid, temperature and flow regime, which is why this calculator uses it.

Does it work for air and gases?

Yes, as long as the pressure drop is small compared with the absolute pressure (less than 10 %), because the density is taken as constant. The air in the list is at 20 °C and atmospheric pressure; if it is compressed, choose “Other” and enter its real density.