Pipe pressure drop calculator with fittings
Calculate the pressure drop in a pipe with its elbows, tees and valves (Darcy-Weisbach and Colebrook). Also the flow rate, diameter or maximum length.
Pressure drop is the pressure a pipe “eats up” as it moves a fluid: through friction with the walls and at every elbow, tee or valve along the way. With this calculator you get it for water, air, diesel, oils or any other fluid, and also the other way round: the flow rate that passes with a given drop, the diameter you need to stay below a certain drop, or the maximum pipe length.
How to use the calculator
- Choose the fluid. For water, its temperature is enough; for any other, enter its density and viscosity.
- Choose the pipe material: it sets its roughness, which you can change.
- Of these four values, enter three and leave empty the one you want to calculate: flow rate, inside diameter, length or pressure drop.
- If the pipe has fittings, enter how many of each type. If it runs from one tank to another, select “Tank inlet and outlet”. For a filter or a piece of equipment, add its K coefficient in “Other losses”.
- With the elevation change, the calculator also gives you the total pressure the pump has to supply.
Darcy-Weisbach equation
Where λ is the friction factor (dimensionless), L the pipe length (m), D its inside diameter (m), ΣK the sum of the fitting coefficients, ρ the fluid density (kg/m³) and v the mean velocity (m/s), which comes from the flow rate:
The first term is the major loss (the straight pipe) and the second, the minor loss (the fittings). Divided by ρ · g, the drop is expressed in metres of fluid column (hf).
Friction factor: Colebrook-White
The friction factor depends on the Reynolds number (Re = ρ · v · D / μ) and on the relative roughness ε / D:
The Colebrook equation cannot be solved explicitly: the calculator solves it by iteration, starting from the Swamee-Jain approximation. It is the same as reading the Moody chart, but without reading errors.
Losses in elbows, tees and valves
Each fitting adds Δp = K · ρ · v² / 2. The coefficients are those of Crane TP-410, which depend on the diameter through fT (the fully turbulent friction factor of commercial steel), plus a Hooper K₁ / Re term for slow or viscous flow:
| Fitting | K (Crane) | K at DN 50 |
|---|---|---|
| Standard 90° elbow | 30 · fT + 800 / Re | 0.57 |
| Standard 45° elbow | 16 · fT + 500 / Re | 0.31 |
| Tee, flow through the branch | 60 · fT + 500 / Re | 1.15 |
| Open ball or gate valve | 8 · fT + 300 / Re | 0.15 |
| Open globe valve | 340 · fT + 1500 / Re | 6.5 |
| Swing check valve | 100 · fT + 1500 / Re | 1.9 |
| Inlet from a tank (sharp-edged) | 0.5 + 160 / Re | 0.5 |
| Discharge into a tank | 1 | 1 |
The equivalent length is the straight pipe that would lose the same as the fittings: Le = ΣK · D / λ. For a specific valve, the manufacturer's data (its Kv or its K) is better.
Roughness of materials
| Material | Roughness ε (mm) |
|---|---|
| Copper, brass, PVC, PE, PP | 0.0015 |
| Stainless steel | 0.015 |
| New carbon steel | 0.045 |
| Galvanized steel | 0.15 |
| Cast iron | 0.26 |
| Rusted or scaled steel | 0.5 |
| Concrete | 0.3 to 3 (1 on average) |
Roughness grows over the years: in old steel pipes it is wise to calculate with 0.2 to 0.5 mm.
Worked example
10 m³/h of water at 20 °C through 100 m of steel pipe with a 50 mm inside diameter, with 4 90° elbows and 2 ball valves:
That is about 4.9 m of water column. The fittings are equivalent to 5.9 m of straight pipe.
Recommended velocities
| Service | Velocity (m/s) |
|---|---|
| Pump suction (water) | 0.5 to 1 |
| Pump discharge (water) | 1 to 2.5 |
| Water in buildings | 0.5 to 2 |
| Oils and viscous liquids | 0.5 to 1.5 |
| Compressed air | 6 to 10 |
| Saturated steam | 20 to 40 |
A reasonable pressure drop in water is between 1 and 4 mbar per metre of pipe (10 to 40 m of water column per kilometre).
Frequently asked questions
What is pressure drop?
It is the pressure a fluid loses as it flows through a pipe, because of friction with the walls (major losses) and the changes of direction and cross-section in elbows, tees and valves (minor or local losses). The pump has to supply that pressure for the flow to circulate.
Which formula does the calculator use?
Darcy-Weisbach, Δp = λ · (L / D) · ρ · v² / 2, with the Colebrook-White friction factor λ (or 64 / Re in laminar flow). Fittings add Δp = K · ρ · v² / 2, with the K coefficients from Crane TP-410.
What velocity is recommended in a water pipe?
Between 1 and 2 m/s on the pump discharge and between 0.5 and 1 m/s on the suction. Above 3 m/s the pressure drop, noise, erosion and risk of water hammer increase a lot.
What is the difference from the Hazen-Williams formula?
Hazen-Williams is empirical and only valid for water at room temperature in turbulent flow. Darcy-Weisbach with Colebrook works for any fluid, temperature and flow regime, which is why this calculator uses it.
Does it work for air and gases?
Yes, as long as the pressure drop is small compared with the absolute pressure (less than 10 %), because the density is taken as constant. The air in the list is at 20 °C and atmospheric pressure; if it is compressed, choose “Other” and enter its real density.