Kv and Cv flow coefficient calculator for valves
Calculate the Kv or Cv of a valve from the flow rate and pressures, or the flow rate or pressure for a known Kv. Suggests a globe valve and its opening.
The flow coefficient (Kv in Europe, Cv in the United States) tells you how much liquid a valve lets through for a given pressure drop. It is the figure used to choose a control valve: with this calculator you get it from the flow rate and the inlet and outlet pressures or, the other way round, the flow rate or pressure given by a valve of known Kv. It also suggests a standard globe valve (DN and Kvs) and tells you how far it would have to open.
How to use the calculator
- Choose the liquid: its density is filled in. If it is not listed, choose “Other” and type the density.
- Of these four values, type three: flow rate, inlet pressure, outlet pressure or flow coefficient. The one you leave empty is calculated.
- The coefficient can be entered or read in Kv, Cv or UK Cv: change the unit in its drop-down. Below it you always have the value in the other unit.
- In the drawing, the valve plug moves up or down with the opening, the liquid flows faster with more flow and the gauges show both pressures.
Kv formula
Where Q is the flow rate in m³/h, Δp = p₁ − p₂ the pressure drop across the valve in bar, ρ the density of the liquid and ρ₀ = 1000 kg/m³ that of water. For water, ρ/ρ₀ ≈ 1 and it becomes Kv = Q / √Δp. Solving for the other values:
The inlet and outlet pressures can be gauge or absolute, but both of the same kind: only their difference counts.
Kv and Cv: equivalences
Kv is the flow rate of water in m³/h with a 1 bar pressure drop. Cv is the flow rate of water in US gallons per minute with a 1 psi pressure drop.
| Kv | Cv (US) | Cv (UK) |
|---|---|---|
| 1 | 1.156 | 0.963 |
| 4 | 4.62 | 3.85 |
| 10 | 11.56 | 9.63 |
| 40 | 46.2 | 38.5 |
| 100 | 115.6 | 96.3 |
Worked example
10 m³/h of water (density 998 kg/m³) flow through a valve with 5 bar at the inlet and 4 bar at the outlet:
With a 25 % margin, you need a valve with Kvs ≥ 12.5: the smallest standard one is DN 32 with Kvs 16, which would work at 9.99 / 16 ≈ 62 % open.
How to choose the valve: Kv and Kvs
Kvs is the Kv of the valve fully open (given by the manufacturer). To control well, the valve should not work almost closed or without margin: choose a Kvs between 25 % and 60 % higher than the calculated Kv. The calculator suggests the smallest globe valve with Kvs ≥ 1.25 · Kv from this common series:
| DN | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Kvs | 0.1 to 4 | 6.3 | 10 | 16 | 25 | 40 | 63 | 100 | 160 | 250 | 360 | 630 | 1000 | 1440 |
The opening shown is that of a valve with a linear characteristic (Kv proportional to the stroke). With an equal-percentage valve, for the same Kv, the plug rises somewhat more. Always check the exact Kvs in the manufacturer's catalog.
Frequently asked questions
What is the Kv of a valve?
It is the flow rate of water, in m³/h, that passes through the valve with a pressure drop of 1 bar. A valve with Kv = 10 lets 10 m³/h of water through when there is a 1 bar difference between inlet and outlet.
How do you convert Cv to Kv?
Kv = 0.865 · Cv and Cv = 1.156 · Kv. Cv is the flow rate in US gallons per minute with a 1 psi pressure drop; Kv, in m³/h with 1 bar.
What is the difference between Kv and Kvs?
Kv is the coefficient your system needs; Kvs is the coefficient of the valve fully open (a manufacturer’s figure). Choose a valve with a Kvs between 25 % and 60 % higher than the calculated Kv, so that it does not work almost closed or without margin.
Does it work for gases and steam?
No: this formula is for liquids. In gases and steam the density changes as the pressure drops, and other formulas are used (IEC 60534 standard).
What happens if the pressure drop is very large?
The liquid can boil inside the valve (cavitation) and the flow rate stops increasing even if you lower the outlet pressure further. If the pressure drop is more than half the absolute inlet pressure, check with the manufacturer.