Skip to content
EN
  • Español
  • English
Advertisement

Open channel and partially full pipe calculator (Manning)

Calculate the flow rate of a rectangular or trapezoidal channel or a partially full pipe with the Manning equation. Also the water depth, slope or roughness.

Fill in 3 of the 4 fields and the missing one is calculated. You can type in any of them.

s/m^(1/3)
1 % = 1 m drop per 100 m.
%
Mean velocity—
Wetted area—
Wetted perimeter—
Hydraulic radius—
Froude number (> 1: supercritical flow)—
Pipe fill—

Use this calculator for reference only, as we cannot guarantee that the results are free of errors.

Disclaimer

https://dyaii.es/en/manning-open-channel-calculator/

Advertisement

In a channel, a ditch or a sewer the water is not under pressure: it flows by gravity, with a free surface. Its flow rate depends on the shape of the cross-section, the water height (the depth), the slope and the roughness of the walls. The Manning equation links them all and is the one used to size channels, culverts and sewer pipes.

How to use the calculator

  1. Choose the cross-section: rectangular, trapezoidal or circular (a partially full pipe) and enter its dimensions.
  2. Choose the material: it sets its Manning coefficient n, which you can change.
  3. Of flow rate, depth, slope and n coefficient, leave empty the one you want to calculate.

Manning equation

Q = (1 / n) · A · R2/3 · √S

Where Q is the flow rate (m³/s), n the Manning roughness coefficient, A the wetted area (m²), R = A / P the hydraulic radius (m), P the wetted perimeter (m) and S the slope (m/m). The mean velocity is v = Q / A.

Cross-sectionWetted area AWetted perimeter P
Rectangularb · yb + 2 · y
Trapezoidal(b + z · y) · yb + 2 · y · √(1 + z²)
CircularD² / 8 · (θ − sin θ)D · θ / 2

In the circular section, θ = 2 · arccos(1 − 2 · y / D) is the angle (in radians) covered by the water.

Advertisement

Manning coefficients

Materialn
PVC, PE0.009 to 0.011
Steel, cast iron0.012
Smooth concrete0.013
Brick, masonry0.015
Rough or shotcrete concrete0.017
Clean earth0.022
Earth with grass0.030
Natural stony stream bed0.035 to 0.050

Worked example

Rectangular concrete channel (n = 0.013), 1 m wide, with 0.3 m of water and a 0.5 % slope:

A = 1 · 0.3 = 0.3 m² · P = 1 + 2 · 0.3 = 1.6 m · R = 0.1875 m
Q = (1 / 0.013) · 0.3 · 0.18752/3 · √0.005 ≈ 0.535 m³/s

That is 535 L/s at a velocity of 1.78 m/s.

In sewers, the velocity should be between 0.6 m/s (so that solids do not settle) and 3 to 5 m/s (so that the pipe does not erode), and pipes should not be more than 75 to 80 % full.
Advertisement

Frequently asked questions

What is the hydraulic radius?

The wetted area divided by the wetted perimeter (R = A / P). In a full pipe it is D / 4. The larger it is, the less friction the water has with the walls.

Why does a pipe carry more flow when almost full than when completely full?

Because when it fills completely the wetted perimeter suddenly grows (it touches the crown) and the hydraulic radius drops. The maximum flow rate of a circular pipe occurs at 94 % fill.

What is the Froude number?

It compares the water velocity with that of a wave on its surface. Below 1 the flow is slow (subcritical); above 1, fast (supercritical), with a risk of hydraulic jumps.

Related calculators

Share

WhatsApp X LinkedIn Telegram Email
Advertisement

Install Diseño y automatización de instalaciones industriales on your phone

All the calculators one tap away, full screen, like an app. It takes no space and is always up to date.