Pipe velocity, flow rate and diameter calculator
Calculate the fluid velocity in a pipe from the flow rate and diameter, the flow rate at a given velocity or the diameter needed for a flow rate.
The flow rate, velocity and diameter of a pipe are linked by a simple formula: the flow rate is the velocity times the cross-section. With this calculator you get any of the three from the other two, in the unit you want: the water velocity in a pipe, the flow rate that passes or the diameter you need to stay below a certain velocity.
How to use the calculator
- Enter two of the three values: flow rate, inside diameter or velocity.
- Leave empty the one you want to calculate. Change the units in the drop-down lists.
- Below you have the diameter that would give 1.5 m/s, a typical velocity on a water pump discharge.
Pipe flow rate formula
Where Q is the flow rate (m³/s), v the mean velocity (m/s), A the inside cross-section (m²) and D the inside diameter (m). Solving:
Worked example
10 m³/h of water through a pipe with a 50 mm inside diameter:
To bring it down to 1 m/s you would need D = √(4 · 0.002778 / π) ≈ 59.5 mm, that is, a DN 65.
Recommended velocities
| Service | Velocity (m/s) |
|---|---|
| Pump suction (water) | 0.5 to 1 |
| Pump discharge (water) | 1 to 2.5 |
| Water in buildings | 0.5 to 2 |
| Oils and viscous liquids | 0.5 to 1.5 |
| Compressed air | 6 to 10 |
| Saturated steam | 20 to 40 |
| Superheated steam | 30 to 60 |
Water flow rate by diameter at 1.5 m/s
| Inside diameter (mm) | Flow rate (m³/h) | Flow rate (L/s) |
|---|---|---|
| 20 | 1.70 | 0.47 |
| 25 | 2.65 | 0.74 |
| 32 | 4.34 | 1.21 |
| 40 | 6.79 | 1.88 |
| 50 | 10.6 | 2.95 |
| 65 | 17.9 | 4.98 |
| 80 | 27.1 | 7.54 |
| 100 | 42.4 | 11.8 |
| 150 | 95.4 | 26.5 |
| 200 | 170 | 47.1 |
Frequently asked questions
Which diameter do I use, nominal or inside?
The inside diameter. The nominal diameter (DN) is only a designation: a DN 50 steel pipe is about 53 mm inside, and a 63 mm PE pipe about 51 mm.
What velocity is recommended?
For water, 0.5 to 1 m/s on the suction and 1 to 2.5 m/s on the discharge; for compressed air, 6 to 10 m/s; for saturated steam, 20 to 40 m/s.
If I double the diameter, how much does the velocity drop?
To a quarter, because the cross-section grows with the square of the diameter. And the pressure drop falls about 30 times.