Pipe velocity, flow rate and diameter calculator

Calculate the fluid velocity in a pipe from the flow rate and diameter, the flow rate at a given velocity or the diameter needed for a flow rate.

Fill in 2 of the 3 fields and the missing one is calculated. You can type in any of them.

Inside cross-section—
Diameter for 1.5 m/s (water, pump discharge)—
Reynolds number—
Mass flow rate—
Fluid density—
Fluid dynamic viscosity—

Use this calculator for reference only, as we cannot guarantee that the results are free of errors.

Disclaimer

https://dyaii.es/en/pipe-velocity-calculator/

Advertisement

The flow rate, velocity and diameter of a pipe are linked by a simple formula: the flow rate is the velocity times the cross-section. With this calculator you get any of the three from the other two, in the unit you want: the water velocity in a pipe, the flow rate that passes or the diameter you need to stay below a certain velocity.

How to use the calculator

  1. Enter two of the three values: flow rate, inside diameter or velocity.
  2. Leave empty the one you want to calculate. Change the units in the drop-down lists.
  3. Below you have the diameter that would give 1.5 m/s, a typical velocity on a water pump discharge.

Pipe flow rate formula

Q = v · A = v · π · D² / 4

Where Q is the flow rate (m³/s), v the mean velocity (m/s), A the inside cross-section (m²) and D the inside diameter (m). Solving:

v = 4 · Q / (π · D²) · D = √(4 · Q / (π · v))
To convert m³/h to m³/s, divide by 3600. It is the most common mistake in this calculation.
Advertisement

Worked example

10 m³/h of water through a pipe with a 50 mm inside diameter:

v = 4 · (10 / 3600) / (π · 0.05²) ≈ 1.41 m/s

To bring it down to 1 m/s you would need D = √(4 · 0.002778 / π) ≈ 59.5 mm, that is, a DN 65.

ServiceVelocity (m/s)
Pump suction (water)0.5 to 1
Pump discharge (water)1 to 2.5
Water in buildings0.5 to 2
Oils and viscous liquids0.5 to 1.5
Compressed air6 to 10
Saturated steam20 to 40
Superheated steam30 to 60

Water flow rate by diameter at 1.5 m/s

Inside diameter (mm)Flow rate (m³/h)Flow rate (L/s)
201.700.47
252.650.74
324.341.21
406.791.88
5010.62.95
6517.94.98
8027.17.54
10042.411.8
15095.426.5
20017047.1
Advertisement

Frequently asked questions

Which diameter do I use, nominal or inside?

The inside diameter. The nominal diameter (DN) is only a designation: a DN 50 steel pipe is about 53 mm inside, and a 63 mm PE pipe about 51 mm.

What velocity is recommended?

For water, 0.5 to 1 m/s on the suction and 1 to 2.5 m/s on the discharge; for compressed air, 6 to 10 m/s; for saturated steam, 20 to 40 m/s.

If I double the diameter, how much does the velocity drop?

To a quarter, because the cross-section grows with the square of the diameter. And the pressure drop falls about 30 times.

Related calculators

Share