Orifice plate flow meter calculator
Calculate the flow rate measured by an orifice plate from the differential pressure, the differential pressure for a flow rate or the bore, with the permanent loss (ISO 5167).
The orifice plate is the simplest and most widely used flow meter in industry: a plate with a calibrated hole between two flanges and a transmitter that measures the pressure difference between before and after. With this calculator you get the flow rate from the differential pressure, the differential pressure a flow rate will give (to choose the transmitter range) or the orifice diameter.
How to use the calculator
- Choose the liquid and enter the pipe inside diameter.
- Adjust the discharge coefficient if the manufacturer gives it (0.61 by default).
- Of orifice diameter, differential pressure and flow rate, leave empty the one you want to calculate.
Orifice plate formula
Where Q is the flow rate (m³/s), C the discharge coefficient, β = d / D the ratio between the orifice and pipe diameters, d the orifice diameter (m), Δp the differential pressure (Pa) and ρ the liquid density (kg/m³). It is the ISO 5167 equation without the expansibility factor, which is only needed for gases.
Not all the differential pressure is lost: part of it is recovered downstream. The permanent loss is:
Worked example
60 mm plate in a 100 mm pipe (β = 0.6), with water and 250 mbar of differential pressure:
The permanent loss is 62.7 % of the differential: about 157 mbar.
Frequently asked questions
Why does the flow rate go with the square root?
Because the differential pressure grows with the square of the velocity. If the flow rate doubles, the differential pressure is multiplied by four. That is why the transmitter is set up with square root extraction.
What β is recommended?
Between 0.2 and 0.75 according to ISO 5167; 0.4 to 0.7 is usual. With a small β the measurement is more sensitive, but more pressure is lost.
How much pressure is really lost?
Less than the measured differential, because part of it is recovered downstream. With β = 0.6, about 60 % of the differential pressure is lost permanently.