Restriction orifice calculator
Calculate the bore of a restriction orifice (pressure-reducing plate) for a pressure drop and flow rate, the drop an orifice causes or the flow it lets through.
A restriction orifice is a plate with a hole that is fitted between two flanges so that the liquid loses pressure or to limit the flow rate. It is cheaper than a valve and never goes out of adjustment. With this calculator you get the bore for the drop and flow rate you need, the drop an orifice you already have will cause, or the flow rate it will let through.
How to use the calculator
- Choose the liquid (or enter its density) and the pipe inside diameter.
- Of flow rate, pressure drop and orifice diameter, enter two and leave empty the one you want to calculate.
Orifice pressure drop formula
Where Δp is the permanent pressure loss (Pa), ρ the density (kg/m³), v the velocity in the pipe (m/s), d the orifice diameter and D the pipe diameter. It is the Idelchik correlation for a sharp-edged orifice in a thin plate: it already includes the pressure recovery downstream.
Worked example
Reducing 1 bar with 10 m³/h of water in a 50 mm pipe:
K coefficient by diameter ratio
| β = d / D | K |
|---|---|
| 0.2 | 1,714 |
| 0.3 | 313 |
| 0.4 | 88.2 |
| 0.5 | 30.7 |
| 0.6 | 11.8 |
| 0.7 | 4.67 |
| 0.8 | 1.73 |
Frequently asked questions
What is a restriction orifice for?
To limit the flow or reduce pressure in a line without a control valve: pump returns (minimum flow recirculation), drains, sampling points or splitting the flow between branches.
Can it cavitate?
Yes. If the pressure in the vena contracta falls below the vapour pressure of the liquid, bubbles form and implode, eroding the plate and the pipe. For large drops (more than 30 to 40 % of the inlet pressure), several orifices in series are used.
And with gases?
The formula is for liquids. With gases it is an approximation if the drop is less than 10 % of the absolute pressure; for more, orifices in series or a compressible flow calculation are used.