Skip to content
EN
  • Español
  • English
Advertisement

Normal to actual gas flow converter (Nm³/h to m³/h)

Convert a gas flow rate from Nm³/h (normal conditions) to actual m³/h at its pressure and temperature, and back. For compressed air, natural gas or nitrogen.

Fill in 3 of the 4 fields and the missing one is calculated. You can type in any of them.

In m³/h it is equivalent to Nm³/h (or Sm³/h).
1 for an ideal gas (air up to about 20 bar).
Absolute pressure—
Ratio Qn / Q (times it is compressed)—
Mass flow rate if it is air—

Use this calculator for reference only, as we cannot guarantee that the results are free of errors.

Disclaimer

https://dyaii.es/en/normal-to-actual-gas-flow-converter/

Advertisement

Compressors, gas flow meters and natural gas bills speak in Nm³/h: “normal” cubic metres, measured at 0 °C and atmospheric pressure. But the gas flowing through the pipe is compressed and takes up much less space. This calculator converts one flow rate into the other, both ways, so you can size pipes, valves and filters with the actual flow rate.

How to use the calculator

  1. Choose the reference conditions: normal (0 °C) or standard (15 or 20 °C).
  2. Enter the gas pressure (say whether it is gauge or absolute) and its temperature.
  3. Enter the normal flow rate to get the actual one, or the actual one to get the normal one. You can also leave the pressure or temperature empty and calculate it.

Normal flow rate formula

Q = Qn · (Pn / P) · (T / Tn) · Z

Where Q is the actual flow rate (m³/h), Qn the flow rate at reference conditions (Nm³/h), Pn = 1.01325 bar the reference pressure, P the absolute gas pressure, T its absolute temperature (K), Tn the reference temperature (273.15 K for Nm³) and Z the compressibility factor (1 for an ideal gas).

Pressures are always absolute and temperatures in kelvin: P abs = P gauge + 1.01325 bar and T (K) = T (°C) + 273.15.
Advertisement

Reference conditions

NameTemperaturePressureStandard
Normal (Nm³)0 °C1.01325 barDIN 1343
Standard (Sm³)15 °C1.01325 barISO 13443 (natural gas)
Compressed air standard20 °C1.01325 barISO 8778 (ANR)

Worked example

A compressor delivers 100 Nm³/h of air at 7 bar gauge and 20 °C:

P = 7 + 1.01325 = 8.01325 bar abs · T = 293.15 K
Q = 100 · (1.01325 / 8.01325) · (293.15 / 273.15) ≈ 13.57 m³/h

13.6 actual m³/h flow through the pipe: that is the flow rate to use for the velocity and the pressure drop.

Advertisement

Frequently asked questions

What is an Nm³?

A normal cubic metre: the amount of gas that takes up 1 m³ at 0 °C and 1.01325 bar absolute. It is a measure of the amount of gas (of mass), not of real volume.

Is an Nm³ the same as an Sm³?

No. The Sm³ (standard cubic metre) is taken at 15 °C (ISO 13443) and is 5.5 % larger than the Nm³. For compressed air, 20 °C is sometimes used (ANR, ISO 8778).

Why do I have to add the atmospheric pressure?

Because the gas law uses absolute pressure. 7 bar on the gauge is 8.01 bar absolute: the air is compressed 8 times, not 7.

Related calculators