Skip to content
EN
  • Español
  • English
Advertisement

Water heating calculator (flow rate, power and steam)

Calculate the power needed to heat a water flow from one temperature to another, the flow a given power can heat or the outlet temperature, and the steam needed.

Fill in 3 of the 4 fields and the missing one is calculated. You can type in any of them.

Water mass flow rate—
Steam needed—
Energy per m³ of water—

Use this calculator for reference only, as we cannot guarantee that the results are free of errors.

Disclaimer

https://dyaii.es/en/water-heating-power-calculator/

Advertisement

To heat water in a heat exchanger, an electric heater or a boiler you need to know how much power it takes. It depends only on how much water flows and how many degrees it rises. With this calculator you get the power, the flow rate you can heat with a given power or the temperature at which the water leaves, and the steam it uses if it is heated with steam.

How to use the calculator

  1. Enter the flow rate and the inlet and outlet temperatures to get the power.
  2. Or enter the power and leave the flow rate or one of the temperatures empty.
  3. If it is heated with steam, enter its pressure and you will see the kg/h of steam needed.

Formula for the power to heat water

P = ṁ · cp · (T₂ − T₁) · with ṁ = ρ · Q

Where P is the power (W), ṁ the mass flow rate (kg/s), cp = 4180 J/(kg·K) the specific heat of water, T₁ and T₂ the inlet and outlet temperatures (°C), ρ the water density at the mean temperature (kg/m³) and Q the flow rate (m³/s). In practical units:

P (kW) ≈ 1.16 · Q (m³/h) · ΔT (°C)

The steam needed is the power divided by the latent heat of the steam at its pressure: ṁ steam = P / hfg.

Advertisement

Worked example

Heating 5 m³/h of water from 15 to 60 °C with steam at 3 bar:

ρ (37.5 °C) ≈ 993.1 kg/m³ → ṁ = 5 / 3600 · 993.1 ≈ 1.379 kg/s
P = 1.379 · 4180 · 45 ≈ 259,400 W ≈ 259 kW
ṁ steam = 259.4 / 2133 · 3600 ≈ 438 kg/h
These are the kW the water receives. To choose the equipment, add the losses: almost nothing with an electric heater, 5 to 10 % with a gas boiler and somewhat more with a poorly insulated steam exchanger.
Advertisement

Frequently asked questions

How many kW does it take to heat 1 m³/h of water by 1 °C?

About 1.16 kW. That is the quick rule: P (kW) ≈ 1.16 · Q (m³/h) · ΔT (°C).

Which specific heat does the calculator use?

4.18 kJ/(kg·K), that of liquid water between 0 and 100 °C (it varies by less than 1 %), with the water density at the mean temperature.

How is the steam calculated?

By dividing the power by the latent heat of the steam at its pressure (ṁ steam = P / hfg), assuming the condensate leaves at its saturation temperature.

Related calculators

Share

WhatsApp X LinkedIn Telegram Email
Advertisement

Install Diseño y automatización de instalaciones industriales on your phone

All the calculators one tap away, full screen, like an app. It takes no space and is always up to date.