Three resistors connected in delta (Δ) between terminals A, B and C can be replaced by three in wye (Y, also called star) that behave the same from the outside, and vice versa. It is Kennelly’s transformation, essential for solving bridges and networks that cannot be reduced with series and parallel, and for calculating three-phase loads per phase. This calculator does it both ways, with resistors or with impedances R + jX.
How to use the calculator
- Choose the direction: from delta to wye or from wye to delta.
- Choose whether they are resistors or impedances (with impedances, also enter the reactance of each branch: positive if inductive and negative if capacitive).
- Enter the three starting values. The equivalents appear in the results and in the drawing, next to their branch.
In the delta, each side joins two terminals (RAB between A and B, RBC between B and C, RCA between C and A). In the wye, each branch goes from a terminal to the center point (RA, RB and RC).
Delta to wye formulas
Each wye branch is the product of the two delta sides that touch its terminal divided by the sum of all three.
Wye to delta formulas
Each delta side is the sum of the products of the branches taken two at a time divided by the branch of the opposite terminal.
Worked example
A delta with RAB = 30 Ω, RBC = 60 Ω and RCA = 90 Ω. The sum is 180 Ω:
Check the other way: RA · RB + RB · RC + RC · RA = 150 + 300 + 450 = 900, and RAB = 900 / 30 = 30 Ω, RBC = 900 / 15 = 60 Ω, RCA = 900 / 10 = 90 Ω. Between A and B, the delta gives 30 ∥ (60 + 90) = 25 Ω and the wye 15 + 10 = 25 Ω: they are equivalent.
Three-phase loads in delta and in wye
A balanced three-phase load with impedance Z per phase in delta is equivalent to one in wye of Z / 3. That is why a motor started in wye draws one third of the current and torque it would in delta (star-delta starting). With unbalanced loads, the conversion lets you calculate the line currents with the circuit in wye, phase by phase.
Frequently asked questions
What is the delta-wye conversion used for?
To simplify circuits that cannot be reduced with series and parallel resistors alone, such as an unbalanced Wheatstone bridge, and to convert three-phase loads from one connection to the other and calculate them per phase.
What is the wye equivalent of three equal resistors in delta?
One third: three 30 Ω resistors in delta are equivalent to three 10 Ω resistors in wye. The other way round, the wye is multiplied by three.
Are the two connections completely identical?
They are equivalent as seen from the three terminals A, B and C: between each pair of terminals there is the same resistance and the same line currents flow. Not inside: the currents and voltages of each branch are different, and the wye has a center point that the delta does not have.
Does it work for impedances with inductors and capacitors?
Yes, with the same formulas in complex numbers. Choose “Impedances (R + jX)” and enter the resistance and reactance of each branch (positive if inductive, negative if capacitive) at the operating frequency.